APPLICATIONS
Concrete and soild pumps
FLOW MEDIUM
Concrete
INNER LINING
Special elastomer, black, highly abrasion resistant (acc. to DIN ISO 4649-A: <90mm³), homogenous, smooth
REINFORCEMENTS
high tension steel wire
COVER
Spezial elastomer, black, fabric patterned, abrasion resistant, resistant to ozone, weather and UV
FURTHER PROPERTIES
Available flange systems: Victaulic, Heavy Duty (US), etc., Couplings are partly hardend and with galvanized sleeve, Fixed lengths with built-in couplings acc. to customers request
WORKING PRESSURE UP TO
85 bar / 1,233 psi
TEMPERATURE RANGE
from -40 °C / -40 °F up to +65 °C / +149 °F
nominal width |
inner-Ø |
wall thickness |
length |
working pressure |
min. burst pressure |
min. bending radius |
weight |
zoll/inch |
mm |
mm |
m |
bar/psi |
bar/psi |
aprx.
mm |
aprx.
g/m |
2
|
50
|
10.0
|
40
|
85/1,233
|
170/2,466
|
350
|
3,000
|
2 5/8
|
65
|
10.0
|
40
|
85/1,233
|
170/2,466
|
450
|
3,700
|
3
|
75
|
11.0
|
40
|
85/1,233
|
170/2,466
|
450
|
4,500
|
3 1/4
|
80
|
12.0
|
40
|
85/1,233
|
170/2,466
|
500
|
5,400
|
4
|
100
|
14.0
|
40
|
85/1,233
|
170/2,466
|
650
|
7,800
|
5
|
125
|
14.0
|
40
|
85/1,233
|
170/2,466
|
800
|
9,600
|
6
|
150
|
16.0
|
40
|
85/1,233
|
150/2,176
|
1000
|
12,400
|
Pressure and vacuum based on room temperature / High pressure and/or temperature lead to reduced component durability